Type: | Dew Point Sensor |
---|---|
Measuring Medium: | Dew Point |
Accuracy: | ±2ºCtd (Standard) |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Dew point measurement range | -80 ~ +20ºCTd (standard) | |
Temperature range of the gas being measured | -40~+60 ºC | |
Dew point accuracy (air or nitrogen) | ±2ºCtd (standard) | |
Response time[63%(90%), gas temperature +20ºC, pressure 1bar] | -60 to -30ºCtd | 20s(40s) |
-30 to -60ºCtd | 5 minutes (20 minutes) | |
Output | Analog output | 4~20mA (three-wire system) |
Current output resolution | 0.002 mA | |
Current output temperature drift | 0.01% of span/ºC | |
Current output load | Not more than 500Ω | |
Digital output | RS-485 | |
Power supply | Electric heating | 12~24V/250mA |
Normal measurement | 12~24V/30mA | |
Working environment | Operating temperature | -40~60ºC |
Storage temperature | -40~60ºC | |
Relative humidity ranges from | 0-95%RH | |
Sample gas flow rate | >1 L/min | |
Pressure | 0-50bar | |
shell | Stainless steel | |
Protection class | IP65 | |
Connection of mechanical parts | ISO G1/2" | |
Stainless steel mesh filter | Filtration grade 40-50um | |
Electromagnetic compatibility | Comply with IEC 61326-1 |
PIN | 1 | 2 | 3 | 4 | 5 |
Signal | VCC12-24V | RS485+ | GND | RS485- | OUT |
Description | Positive | RS485+ | Negative | RS485 | Current output |
Suppliers with verified business licenses