• Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
  • Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
  • Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
  • Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
  • Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
  • Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

Sensitivity: High
Certification: CE
Customized: Customized
Samples:
US$ 289/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor pictures & photos
Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
US $245-289 / Piece
Min. Order: 1 Piece
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Wiring Method
  • Application Fields
  • Company Profile
  • FAQ
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Veinasa-NVOC
The Maximum Power Consumption
(Default) DC 10-30V
Signal Output
RS485 Output (Standard Modbus RTU Protocol)
Installation Method
Bracket Installation
Minimum Detection Particle
No2: 0.1ppm;
Transport Package
Covered with Carton Package
Specification
1.1 KG
Trademark
Veinasa
Origin
China
Production Capacity
1000pieces/Years

Product Description

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality SensorVeinasa-NVOC Indoor VOC Sensor Monito  Digital NO2 Sensor Air Quality Sensor
Product Description

 

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality SensorThe integrated louver can be widely used in environmental detection, for the detection of TVOC, formaldehyde (CH20), ozone (03), oxygen (02), hydrogen sulfide (H2S), methane (CH4), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), hydrogen (H2), ammonia (NH3) and other parameters in the environment.
It is installed in the louver, and the equipment adopts standard MODBUS-RTU Communication protocol, RS485 signal output, communication distance up to 2000 meters (measured).

 

Product Parameters
Item Item
Measuring range NO2:0~20ppm
TVOC:0~60000ppb
 
Relative error NO2:±3%FS
TVOC:±8%FS±125ppb
Minimum detection particle NO2:0.1ppm
TVOC:1ppb
The maximum power consumption (default) DC 10-30V
The detection parameters Less than 0.8W TVOC; NO2
Working environment: Temperature - 10 ºC - 55 ºC; humidity 0 ~ 95% RH, non condensing
Signal output RS485 output (standard Modbus RTU protocol)
Material ABS
Installation method Bracket installation
Wiring Method

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

Wide - voltage power supply input 10-30V. 485 when wiring the signal line, notice that the two lines of AIB cannot be connected in reverse, and the addresses of multiple devices on the bus cannot conflict.
  The line color Instructions
Electricity the source Brown Power positive(10~30V DC)
Black The power negative
Tong the letter Yellow 485 - A
Blue 485 -B
Application Fields

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

The transmitter is widely used to measure the ambient air quality and other occasions, safe and reliable, beautiful appearance, easy to install, durable.
Company Profile

 

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality SensorVeinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality SensorVeinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor
FAQ

Q: Are you a factory/manufacturer?

A: Yes, we are professional factory/manufacturer of weather station and relative weather sensors. We also have hot sale and widely used weather station AWS005S.

Q: What's the common power supply and signal output?
A: Common power supply and signal output is DC12-24V, RS485. But we can customize for you as demands.

Q: How can I collect data?
A: If you have your own data logger, you only need to buy our sensor and meanwhile we send you communication protocol.
If you do not have, we can add our data logger for you, also provided with English software, which can help you read, inquire and download data.

Q: What's the lifetime of this air quality monitoring equipment?
A: At least 5 years long. Every sensor has its own calibration certificate or testing report.

Q:What's the delivery time?
A: Usually, we dispatch goods in 3-5 working days after receiving your payment. But it depends on your quantity.

Q: May I know your warranty?
A: Yes, usually it's 1 year. We can send you detailed warranty document if needed.

With rich experiences in tackling problems, Veinasa aims to provide a package of meteorological solutions to your needs, whatever problems you encounters, Veinasa team always stand by your side.

Just click the below picture to send us inquiry, to know more, or get the latest catalogue and competitive quotation. Do not hesitate!
Packaging & Shipping

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

Veinasa-Nvoc Indoor Voc Sensor Monito Digital No2 Sensor Air Quality Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now