Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor

Product Details
Customization: Available
Measuring Principle: Dual Wavelength Ultraviolet Absorption Method
Cod Measuring Range: 0-100mg/L Equiv. Khp
Still deciding? Get samples of US$ 2246/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (11)
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
  • Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product Display
  • Application Fields
  • Company Profile
  • FAQ
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Veinasa-COD
Turbidity Range
0-100ntu
Calibration Method
Two-Point Calibration
Output Method
RS-485 Bus, Modbus/RTU Protocol
Power Supply
12VDC±10%
Power Consumption
<0.5W
Working Conditions
0-45ºC, <0.2MPa
Storage Temperature
-5-65ºC
Protection Level
IP68
Transport Package
Covered with Carton Package
Specification
185*32mm
Trademark
Veinasa
Origin
China
Production Capacity
1000pieces/Years

Packaging & Delivery

Package Size
20.00cm * 18.00cm * 15.00cm
Package Gross Weight
1.700kg

Product Description

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature SensorVeinasa-COD UV Fluorescence Online COD Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
Product Description

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature SensorMany organic substances dissolved in water absorb ultraviolet light. Therefore, by measuring the absorption of these organic substances by ultraviolet light at a wavelength of 254 nm, the total amount of dissolved organic pollutants in water can be accurately measured.

 
Veinasa-COD UV Fluorescence Online COD Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor is a online COD sensor.The online COD sensor uses two light sources, one 254nm ultraviolet light and one 365nm ultraviolet reference light, which can automatically compensate the optical path attenuation and eliminate the interference of the granular suspended matter enamel to a certain extent, thus achieving more stable and reliable.
Product Parameters
Model COD-302
Measuring principle Dual wavelength ultraviolet absorption method
COD Measuring range 0-100mg/L equiv. KHP
COD Precision ±5%F.S.
COD Resolution 0.1mg/L
Turbidity range 0-100NTU
Turbidity accuracy ±5%F.S.
Turbidity resolution 0.1NTU
Calibration method Two-point calibration
Output method RS-485 bus, Modbus/RTU protocol
Power supply 12VDC±10%
Power consumption <0.5W
Working conditions 0~45ºC,<0.2MPa
Storage temperature -5~65ºC
Protection level IP68
Installation method Immersion installation
Cable length 5 meters, other lengths can be customized
Sensor housing material  316L stainless steel
Product Display

 

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
Features of Veinasa-COD UV Fluorescence Online COD Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor:
 
No reagents, no pollution, more economical and environmental protection
Small size, easy installation, and continuous water quality monitoring
Measure COD, turbidity and temperature parameters Automatic compensation for turbidity interference
With a cleaning brush to prevent bio-adhesion Small drift, fast response, more accurate measurement
Excellent stability even for long-term monitoring
Maintenance-free, long service life and low cost of use
Digital sensor, RS-485 interface, Modbus/RTU protocol
Low power design, anti-interference design

 
Application Fields

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature SensorVeinasa-COD UV Fluorescence Online COD Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor can be applied to:

Irrigation
Fish Pool
Chemistry experiment
Drinking water
chemistry experiment
Sewage treatment
Industrial wastewater treatment
Company Profile

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature SensorVeinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor
FAQ

Q: Are you a factory/manufacturer?
A: Yes, we are a professional factory/manufacturer of water quality sensors. We also have hot sale and widely used water quality sensor Veinasa-PH.

Q: What are the power supply output and common signal output?
A: The common power supply output and signal output are 12VDC±10% and RS485 respectively. But we can customize for you as demands.

Q: How can I collect data?
A: If you have your own data logger, you only need to buy our sensor and meanwhile we send you communication protocol. If you do not have, we can add our data logger for you, also provided with English software, which can help you read, inquire and download data.

Q: What's the lifetime of this online COD sensor?
A: At least 5 years long. Every sensor has its own calibration certificate or testing report.

Q:What's the delivery time? A: Usually, we dispatch goods in 3-5 working days after receiving your payment. But it depends on your quantity.

Q: May I know your warranty?
A: Yes, usually it's 1 year. We can send you detailed warranty document if needed.

With rich experiences in tackling problems, Veinasa aims to provide a package of meteorological solutions to your needs, whatever problems you encounters,Veinasa team always stand by your side.

Just click the below picture to send us inquiry, to know more, or get the latest catalogue and competitive quotation. Do not hesitate!

Packaging & Shipping

 

Veinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature SensorVeinasa-Cod UV Fluorescence Online Cod Water RS485 Modbus Portable Turbidity Meter Quality Analyzer Temperature Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier