Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor

Product Details
Customization: Available
After-sales Service: Please Contact Customer Service.
Warranty: 1 Year
Still deciding? Get samples of US$ 89/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (11)
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
  • Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product Display
  • Application case
  • Company Profile
  • FAQ
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
Veinasa-GDPM
Brand
Veinasa
Customized
Customized
Portable
Non Portable
Gas
Pm2.5 Pm10
Power Supply (Default)
10~30V DC
Power Waste
0.5W
Operating Temperature
-20 ºC ~ + 60 ºC
Operating Humidity
0% Rh ~ 95% Rh
Communication Interface
RS485 Communication (Modbus) Protocol
Transport Package
Covered with Carton Package
Trademark
Veinasa
Origin
China
Production Capacity
1000pieces/Month

Packaging & Delivery

Package Size
35.00cm * 28.00cm * 25.00cm
Package Gross Weight
2.000kg

Product Description

RS485 Particle Sensor Air Quality Monitor
Product Description

 

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
Veinasa-GDPM Tube Modbus Fixed Dust PM2.5 PM10 Transmitter RS485 Particle Sensor Air Quality Monitor is an industrial general particle concentration transmitter. It adopts the principle of laser scattering measurement and sieves through the unique dual frequency data acquisition technology to obtain the number of particles with equivalent particle size in unit volume, and uses a scientific and unique algorithm to calculate the mass concentration of particles with equivalent particle size in unit volume. The transmitter is professionally used for pipeline particle concentration measurement.
The air quality transmitter adopts wide voltage 10-30V DC power supply, 485 signal output, standard Modbus RTU communication protocol, MODBUS address can be set, baud rate can be changed, and the communication distance is up to 2000m.
Product Parameters

 

DC power supply (default)
10~30V DC
power waste
0.5W
Operating temperature and humidity of transmitter circuit
-20 ºC ~ + 60 ºC, 0% RH ~ 95% RH non condensation
communication interface
485 communication (Modbus) protocol

Baud rate: 2400, 4800 (default), 9600

Data bit length: 8 bits

Parity check method: None

Stop bit length: 1 bit

Default Modbus communication address: 1

Support function code: 03
Parameter setting
Configure through 485 interface with the provided configuration software
Resolution
1ug/m3
Accuracy
±10%(@500ug/m3,60%RH,25ºC)
measuring range
PM2.5
0~1000ug/m3
 
PM10
0~1000ug/m3
response time
≤90S
Preheating time
≤2min
Product Display

 

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
Characterics of this particulate matter transmitter(Veinasa-GDPM):
 
The air quality transmitter adopts waterproof shell design, pipeline installation mode, convenient on-site installation, anti-interference circuit design, and can withstand various strong electromagnetic interference such as on-site frequency converter.
 
 
Other functional features of Veinasa-GDPM:

* Range: 0-1000ug / m3, resolution: 1ug / m3
* PM2.5 and PM10 output simultaneously
* unique dual frequency data acquisition and automatic calibration technology, with consistency of ± 10%
* adopt advanced laser anti attenuation technology to ensure the long-term stability of the equipmen
* standard Modbus RTU communication protocol, easy access

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
Application case

 

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
The applications of Veinasa-GDPM Tube Modbus Fixed Dust PM2.5 PM10 Transmitter RS485 Particle Sensor Air Quality Monitor:
 
As a air quality transmitter Veinasa-GDPM can be applied to air quality monitoring system which is mainly used to measure the concentration of PM2.5 and PM10 in the air. This particulate matter sensor has been widely used in industry, agriculture, meteorological monitoring, aerospace and other industries.
Company Profile

 

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality MonitorVeinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality MonitorVeinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor
FAQ

 

Q: Are you a factory/manufacturer?
A: Yes, we are a professional factory/manufacturer of water quality sensors. We also have hot sale and widely used particulate matter sensor XS-PM10/XS-PM2.5.
 
Q: What are the power supply output and common signal output?
A: The common power supply output and signal output are 10~30VDC and RS485 respectively. But we can customize for you as demands.
 
Q:What is the main function of this particulate matter sensor?(Veinasa-GDPM)
A:This sensor is a fixed dust detector which is always used to detect particulate matter concentration of PM2.5 and PM10.
 
Q: How can I collect data?
A: If you have your own data logger, you only need to buy our sensor and meanwhile we send you communication protocol.
If you do not have, we can add our data logger for you, also provided with English software, which can help you read, inquire and download data.
 
Q: What's the lifetime of this particulate matter sensor(Veinasa-GDPM)?
A: At least 5 years long. Every sensor has its own calibration certificate or testing report.
 
Q:What's the delivery time?
A: Usually, we dispatch goods in 3-5 working days after receiving your payment. But it depends on your quantity.
 
Q: May I know your warranty?
A: Yes, usually it's 1 year. We can send you detailed warranty document if needed.
 
With rich experiences in tackling problems, Veinasa aims to provide a package of meteorological solutions to your needs, whatever problems you encounters, Veinasa team always stand by your side.
 
Just click the below picture to send us inquiry, to know more, or get the latest catalogue and competitive quotation. Do not hesitate!
 
Packaging & Shipping

 

Veinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality MonitorVeinasa-Gdpm Tube Modbus Fixed Dust Pm2.5 Pm10 Transmitter RS485 Particle Sensor Air Quality Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier