Product Name: | Water Turbidity Sensor |
---|---|
Power Supply: | 12~24VDC ±10% |
Signal Output: | RS-485 (Modbus/RTU) |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
The integrated online turbidity sensor is designed and manufactured using the principle of scattered light turbidity measurement. When a beam of light is incident on a water sample, the light is scattered by the turbidity substance in the water sample, and the intensity of the scattered light in the direction perpendicular to the incident light is measured and compared with the internal calibration value to calculate the turbidity in the water sample and output the final value after linearized.
Model
|
Veinasa-ZD06
|
Measuring principle
|
Scattered light method
|
Measuring range
|
0 to 1000 NTU or 0 to 200 NTU
|
Resolution
|
0.1NTU, 0.1°C
|
Precision
|
±3% of reading or ±3NTU, whichever is greater, ±0.5°C
|
Calibration method
|
Two-point calibration
|
Temperature compensation
|
Automatic temperature compensation (Pt1000)
|
Output method
|
RS-485 (Modbus/RTU)
|
Working conditions
|
0 to 50 ° C, <0.2 MPa
|
Storage temperature
|
-5~65°C
|
Installation method
|
Immersion mounting, 3/4" NPT thread
|
Cable length
|
5 meters, other lengths can be customized
|
Power consumption
|
<0.5W
|
Power supply
|
12~24VDC ±10%
|
Protection level
|
IP68
|
Cable color
|
Output signal
|
|
|
||
Red
|
Power+
|
12~24V
|
Black
|
Ground
|
GND
|
Blue
|
|
485A
|
White
|
|
485B
|
Bare wire
|
Shielded wire
|
Suppliers with verified business licenses