• Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
  • Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
  • Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
  • Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors

Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors

Place of Origin: Sichuan, China
Brand Name: Veinasa
Theory: CO2 Sensor
Samples:
US$ 299/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors pictures & photos
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
US $215-299 / Piece
Min. Order: 1 Piece
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Product Display
  • Application Case
  • Company Introduction
  • FAQ
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
XS-PM
Output
RS485
Brand
Particle Sensor for Pm10 or Pm2.5
Product Name
Particle Sensor for Pm10 or Pm2.5
Warranty
1year
Measuring Range
Pm2.5: 0.0-999.9μG/M3;Pm10 : 0.0-1
Relative Error
±15% and ±10μG/M3 Maximum
Minimum Detection Particle
0.3μm Diameter
Power Supply Mode
DC 24V;DC 12V
Communication Mode
RS485, Ttl;Other
Load Resistance
Voltage Type:Rl≥1K;Current Type: R
Ambient Temperature
-20ºC~+60ºC
Power Consumption
350 MW
Transport Package
Covered with Cartoon Package
Trademark
Veinasa
Origin
China

Packaging & Delivery

Package Size
35.00cm * 30.00cm * 25.00cm
Package Gross Weight
1.000kg

Product Description

XS-PM Air Dust Monitoring System PM2.5 PM10 Sensor Particle Sensor for PM10 or PM2.5 Sensors
Product Description

 


Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
XS-PM Air dust monitoring system PM2.5 PM10 sensor particle sensor for PM10 or PM2.5 sensors adopt the principle of laser scattering, which can sensitively detect the concentration of PM2.5 and PM10 in the environment, uses imported lasers and photosensitive parts, and the data is stable and reliable. The built-in fan has high integration; the sensor's supply voltage and output signal can be changed as needed. Supply voltage and the type of signal output.
Product Parameters
Measuring range
PM2.5: 0.0-999.9μg/m3
PM10 : 0.0-1999.9μg/m3
Relative error
PM2.5,PM10:±15% and ±10μg/m3 maximum tolerance (25ºC,50%RH)
Minimum detection particle
0.3μm diameter
Power supply
DC 12V
DC 24V
other
Output format
RS485 , TTL
other
Cable length
standard:2.5 m
other
Load resistance
Voltage type:RL≥1K
Current type: RL≤300Ω
Ambient temperature
-20ºC~+60ºC
Environmental humidity
0~70%
Product power consumption
350 mW (Single sensor is connected to the data logger)
 
Product Display

 

Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 SensorsXS-PM Air dust monitoring system PM2.5 PM10 sensor particle sensor for PM10 or PM2.5 sensors

1. Must be installed vertically.
2. Away from artificial airflow such as fans, such as when used in air fresheners, the front and rear of the fan can not be installed, it can be installed on the side of the shell, but the vents should be kept on the shell to ensure that the external airflow can flow freely.
3. Pay attention to avoid sticky particles such as oil or catkins into the module during installation, when such particles stick to the optical components will cause failure.
4. When the module is wet, it will affect its normal function, so it should avoid moisture.
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
1.If equipped with the data logger produced by our company, directly use the sensor cable to connect the sensor to the corresponding interface on the collector. 2.If the transmitter is purchased separately, the transmitter cable sequence is:
Color
Output signal
0~5V
4~20mA
RS485
Red
+
+
+
Black(green)
-
-
-
Yellow
Voltage signal
Current signal
485+
Blue
 
 
485-

 

3.Pulse voltage and current output connection mode:
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
Application Case

 

 
XS-PM Air Dust Monitoring System PM2.5 PM10 Sensor Particle Sensor for PM10 or PM2.5 Sensors can be applied to the following fields:
 
As a particle sensor for PM10 or PM2.5, XS-PM PM2.5 and PM10 Integrated Air Quality Monitoring System Dust Sensor for Meteo Station can be applied to air quality monitoring system which is mainly used to measure the content of PM2.5 and PM10 in the air.This PM2.5 pm10 sensor has been widely used in industry, agriculture, meteorological monitoring, aerospace and other industries.
 
Company Introduction

 

Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 SensorsXs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 SensorsXs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
FAQ

 

Q: What are the power supply output and common signal output?
A: The common power supply output and signal output are 12~24VDC and RS485 respectively. But we can customize for you as demands.
 
Q: How can I collect data?
A: If you have your own data logger, you only need to buy our sensor and meanwhile we send you communication protocol.
If you do not have, we can add our data logger for you, also provided with English software, which can help you read, inquire and download data.
 
Q: What's the lifetime of this Particle Sensor for PM10 or PM2.5(XS-PM)?
A: At least 5 years long. Every sensor has its own calibration certificate or testing report.
 
Q:What's the delivery time?
A: Usually, we dispatch goods in 3-5 working days after receiving your payment. But it depends on your quantity.
 
Q: May I know your warranty?
A: Yes, usually it's 1 year. We can send you detailed warranty document if needed.
 
With rich experiences in tackling problems, Veinasa aims to provide a package of meteorological solutions to your needs, whatever problems you encounters, Veinasa team always stand by your side.
 
Just click the below picture to send us inquiry, to know more, or get the latest catalogue and competitive quotation. Do not hesitate!
Packaging & Shipping

Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 SensorsXs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors pictures & photos
Xs-Pm Air Dust Monitoring System Pm2.5 Pm10 Sensor Particle Sensor for Pm10 or Pm2.5 Sensors
US $215-299 / Piece
Min. Order: 1 Piece
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Trading Company
Plant Area
200 square meters