Customization: | Available |
---|---|
Product Name: | Air Quality Sensor |
Pm2.5: | 0-1000ug/M 3 |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Monitoring parameter
|
Range
|
Resolution
|
Accuracy
|
Configuration
|
PM2.5
|
0-1000ug/m³
|
1ug/m³
|
±10% measured value
|
Standard
|
PM10
|
0-1000ug/m³
|
1ug/m³
|
±10% measured value
|
Standard
|
Carbon monoxide
|
0-12.5ppm
|
≤10ppb
|
±1.5%F.S
|
Standard
|
Sulfur dioxide
|
0-2000ppb
|
≤10ppb
|
±1.5%F.S
|
Standard
|
Nitrogen dioxide
|
0-2000ppb
|
≤10ppb
|
±1.5%F.S
|
Standard
|
Ozone
|
0-2000ppb
|
≤10ppb
|
±1.5%F.S
|
Standard
|
Temperature
|
-40-60ºC
|
0.1ºC
|
±0.3ºC(25ºC)
|
Standard
|
Relative humidity
|
0-100%RH
|
0.1%
|
±3%RH
|
Standard
|
Remarks
|
It can increase wind speed, wind direction, atmospheric pressure, rainfall, H2S, noise, sunshine radiation, AQI index, ultraviolet radiation index, noise level output and other parameters. For details, please contact our staff. |
Detection principle
|
PM2.5,PM10: laser method measurement; CO,SO2,NO2,O3: electrochemical principle |
Power supply range
|
DC12-24V
|
Work Consumption
|
<1w@12V
|
Signal output
|
Default 485 output, MODBUS protocol Scalable: GPS positioning
|
Scalable parameter
|
Ambient temperature, ambient humidity, H2S, PM100, other VOC, etc.
|
Working environment
|
Temperature -40-70 ° C Humidity 5-90% RH
|
Installation method
|
Barrel type fixing, flange type fixing
|
Shell material
|
ASA material
|
Protection level
|
IP65
|
Added feature |
Can increase the data collector (network port, GPRS wireless communication) The fixed bracket (1.5m, 3m) can be added to form a complete monitoring station type; The B/S architecture software platform and mobile APP client software (limited to Android version) can be added; the solar power supply system can be added. |