Customization: | Available |
---|---|
Installation Type: | Insert Into Soil |
Contact: | Contact |
Still deciding? Get samples of US$ 56/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters
|
|||
Signal output
|
Voltage output 0-2V
Output impedance<1Kohm |
Current output 4-20mA
Load resistance<500ohm |
RS485 interface, Modbus protocol (If RS232, using data communications interface converters)
|
Supply voltage
|
5-30V/DC
|
12-30V/DC
|
5-30V/DC
|
Max power consumption
|
40mA@24V DC
|
80mA@24V DC
(when 2 current output channels both 20mA) |
30mA@24V DC
|
Soil moisture measurement scope
|
A cylinder with a diameter of 20cm and a height of 17cm centered on a central probe
|
||
Response time(moisture and temperature)
|
<1s
|
||
Soil moisture measurement range
|
0-100% moisture volume percentage
|
||
Soil moisture measurement resolution
|
±3% between 0-53%; ±5% between 53-100%
|
||
Soil temperature measurement range
|
-40~80ºC
|
||
Soil temperature measurement accuracy
|
±0.5ºC
|
||
Protection grade
|
IP68
|
||
Operating temperature
|
-40~85ºC
|
||
Storage environment
|
-40~85ºC
|
||
Probe material
|
Food grade stainless steel
|
||
Sealing material
|
Black flame retardant epoxy resin
|
||
Installation method
|
All imbedded or probe inserted into the medium under test
|
Model
|
Wiring diagram
|
Voltage output
|
Red(V+): +
Black(G): ground Blue(O1): output signal(temperature) Brown(O2): output signal(moisture volume percentage) Yellow: Do not connect White: Do not connect Green: Do not connect |
Current output
|
Red(V+): +
Black(G): ground Blue(O1): output signal(temperature) Brown(O2): output signal (moisture volume percentage) Yellow: Do not connect White: Do not connect Green: Do not connect |
RS485 interface, Modbus protocol
|
Red(V+): +
Black(G): ground Blue(O1): Do not connect Brown(O2): Do not connect Yellow(T+): RS485+/A/T+ White (T-): RS485-/B/T- Green (SET): When connecting V+(power is positive), the power on start module enters "setting mode". When not connected or connected to G (power ground), the power start enters "operation mode". The configuration parameters such as Modbus address, baud rate, verification bit, communication protocol, etc. are stored in the EEPROM (power-off storage device) inside the module. Sometimes you forget the specific configuration of these parameters and cannot communicate with the module. To prevent this problem, the module has a special mode called setup mode. When the module starts up in Settings mode, the module will communicate with the following parameters: Modbus address is fixed at 0 Communication configuration is 9600,N,8,1(9600bps,no verification bit,8 data bits,1 stop bit) Communication protocol is Modbus-RTU Configuration parameters in an EEPROM do not change as the module enters "setup mode," and when the module is in "run mode," these configuration parameters in the EEPROM are still communicated. |