Suppliers with verified business licenses
Technique Parameters
|
||
Soil Temperature
|
Range: -40~80°C; Resolution: 0.1°C; Accuracy: ±0.5°C
|
|
Soil Moisture
|
Range: 0-100% RH; Resolution: 0.01% RH; Accuracy: 5%
|
|
Soil Conductivity
|
Range: 0-10000us/cm
|
|
Resolution
|
1us/cm within 0-10000us/cm
|
|
Accuracy
|
±5% in the range of 0-10000us/cm
Conductivity temperature compensation, built-in temperature compensation sensor, compensation range 0-50 °C |
|
Supply Voltage
|
DC5V-24V
|
|
Signal Output
|
RS485, Modbus Protocol
|
|
Measuring Principle
|
Soil moisture FDR method, soil conductivity AC bridge method
|
|
Protection Level
|
IP68 immersed in water for long-term use
|
|
Operating Environment
|
-40~85°C
|
|
Probe Material
|
Anti-corrosion special electrode
|
|
Sealing Material
|
Black flame retardant epoxy resin
|
|
Installation Method
|
All buried or all probes inserted into the measured medium
|
|
Default Cable Length
|
5 meters, cable length can be customized according to requirements
|
|
Connection Method
|
Pre-installed cold-pressed terminal
|
|
Dimensions
|
45*15*135mm
|
|
Electrode Length
|
50mm
|